Skip to main menu Skip to main content Skip to footer

Military, Aerospace & Government - ARCHIVE

Clear-Com intercom systems provide solutions for almost any communications need in the Military, Aerospace and Government world. The system is a specifically-configured communications solution intended to connect individuals who are working on the same project at the same time. As opposed to the classic telephone system, a Clear-Com system can provide a secure, highly reliable, low latent path which allows communication between two or hundreds of people simultaneously.

Latest
News

Keep up with our latest project highlights, event recaps, and company updates.

HXII-RM

HXII-RM

4-Channel 1RU Digital Remote Station

Remote Station

  • Easy to use front panel with OLED displays & backlit keys
  • Headset or hands-free support with speaker and mic
  • 4 Keysets assignable to channels
  • All Talk, Stage Announce, RMK & Program Audio level control
  • Expansion mode for 8-24 channels

Connectivity

  • Ethernet Network port with PoE
  • Powerline loop-through on XLR
  • Program Audio input
  • Stage Announce output
  • Contact closure input & output

HelixNet System

  • Wired Partyline - Networked
  • Hosted by Arcadia or HMS-4X
  • Up to 24 Channels – Licensed
  • Up to 64 or 128 HelixNet Endpoints
  • Program Audio user level control

Effortless Management 

  • Easy to use CCM browser configuration
  • Fast front panel control & configuration
  • Central discovery & pairing on Arcadia
  • Plug-and-go Powerline
  • Central firmware upgrades from host
Previous Article HMS-4X (Call Clear-Com*)
Print
17026 Rate this article:
No rating
Item Code

HXII-RM-X4/HRM-4X (includes): (1) Inline PSU 15W 48V DC (453G026)

Technical Specifications Left
HelixNet System Hosts

Arcadia: Supports up to 128 HelixNet User Stations over Ethernet or Powerline via the HXII-DPL Powerline Device. Up to 24 Channels can be HelixNet Enabled using a Licensed Port for assignment to any HelixNet User Station keyset.

HMS-4X: Supports up to 64 endpoints (Remote Stations, Speaker Stations, Beltpacks, HLI-2W2, HLI-4W2, LQ port). User stations can connect directly to the 2 HMS-4X Powerlines or via optional HLI-ET2 module using HXII-DPL Powerline Device or 3rd party network switch connection. HMS allows use of 12 channels which can be expanded to 24 using optional license.

 
Connectors

XLR Powerline: 3-pin XLR-M/F

Ethernet/PoE: EtherCON RJ45

Headset: 4-pin XLR–M

Gooseneck Mic: 3-pin Tuchel

Program Audio: 3-pin XLR–F

Stage Announce: 3-pin XLR–M

Hot Mic/IFB Interface: 1/4\" (0.64 cm) TRS jack

GPIO: 9-pin D-type male (1xGPI, 1xGPO)

USB: Type A

DC Power: 3-pin KPJX-PM-3-S

 
Microphone Pre-amplifier

Headset Mic Impedance: 200Ω (Dynamic)

Headset Mic Voltage: 1.7V (Electret selectable)

Limiter: +23dB

 

Route to 4-wire output at 0dBu out:

Mic Gain: 60dB (Dynamic), 45dB (Electret)

Frequency Response: 300Hz – 10 kHz ±3dB, contoured for intelligibility

Distortion: <0.2% THD @ 1kHz

Noise: <-55dBu (Dynamic),<-65dBu (Electret)

 
Headphone Amplifier

Load Impedance: >32Ω 

Output Level: +12dBu before clipping

Sidetone: -12dB (selectable)

 

Route from a 4-wire input at 0dBu in:

Max Gain: 0dB

Frequency Response: 180Hz – 10kHz +3dB

Distortion: <0.1% THD @ 1kHz

Noise: <-65dBu

Headphone Limiter: 0dB (selectable)

 
Loudspeaker Amplifier

Load Impedance: 8Ω 

Output Level: +18dBu before clipping

 

Route from a 4-wire input at 0dBu in:

Max Gain: 18dB

Frequency Response: 200Hz - 10kHz ±3dB

Distortion: <0.1% THD @ 1kHz

Noise: <-50dBu

 
Program Audio Line Input

Arcadia System Host: Local Listen Only

HMS-4X System Host: Local or Channel Assignable.

Maximum Level Before Clipping: +18dBu

Nominal Input Level: 0dBu (selectable)

Input Impedance: >= 10KΩ 

 

Route to 4-wire output at 0dBu out:

Frequency Response: 20Hz - 10kHz ±3dB

Distortion: <0.2% THD @ 1kHz

Noise: <-65dBu

 
Stage Announce Output

Arcadia System Host: Local SA or Channel Assignable from front panel or Role

HMS-4X System Host: Local SA or Channel Assignable

Maximum Level Before Clipping: 18dBu

Nominal Output Level: 0dBu (selectable)

Output Impedance: <= 100Ω 

Route from a dynamic headset: Frequency Response: 300Hz - 12kHz ±3dB

Distortion: <0.1% THD @ 1kHz

Noise: <-55dBu

 
Hot Mic Output

Maximum Level Before Clipping: +12dBu

Nominal Output Level: 0dBu (selectable)

Output Impedance: <= 100Ω 

 

Route from a dynamic headset:

Frequency Response: 300Hz - 12kHz ±3dB

Distortion: <0.2% THD @ 1kHz

Noise: <-55dBu

 
Logic Inputs -GPI

Assignable to talk, call, mic and headset keys

Input: 1

Style: Powered input, close contact to ground

Detection Voltage (Min): 3V

Input Voltage (Max): 5V

Output Voltage: 5V

Output Current (Max): 1mA

Technical Specifications Right
Logic Outputs – GPO/Relay

Assignable to talk, call, SA keys and channel events

Outputs: 1

Style: Power Relay

Normalized: Open or Closed, separate pins

Switching Voltage (Max): 30V

Switching Current (Max): 2A

 
Power

Voltage: 48V DC

Current (Max): 0.3A

Power (Max): 14.4W

BTU (Max): 49BTU/hr

Input Power Connector: KPJX-PM-3-S

 

This unit can be powered via:

 

AC Adapter - Inline:

Input Voltage Range: 100 - 240V AC

Input Frequency Range: 50 - 60Hz

Input Power Connector: IEC-C14

Output Voltage: 48V DC

Output Power (Max): 15W

Output Power Connector: KPPX-3-P PoE - Power over Ethernet* IEEE 802.3af-2003 - Class 0

PSE: 15.4W DC max @ Power Source Req.

PD: 12.95W DC max @ Powered Device Draw

 

Powerline:

Input Voltage: ±29.5V DC

Input Current (Speaker Off): 0.3A

Input Current (Max): 0.5A

Powerline Utilization:

Remote Station (Local Power) = 1 beltpack

Remote Station (Speaker Off) = 2 beltpacks

Remote Station (Speaker On) = 3 beltpacks

Note the maximum Powerline capacity of the HMS-4X. Use HelixNet Cable Calculator to validate load and cable distance.

 
Environmental

32º - +104ºF (0 - +40ºC)

90% relative humidity

 
Dimensions

1RU, 1.75 x 19 x 6.4in (HxWxD)

(44 x 483 x 165mm)

 
Weight

4lbs (1.8kg)

 
Network Specifications (Firmware Version 4.5+)
Network Protocols

Ethernet IPv4–Unicast Audio and Control

mDNS–Multicast Device Discovery

Layer 3 routable with mDNS function limitations

HTTP–Management

I.V. Core–Decentralized Network Routing & Mixing

IVP-Proprietary intercom Audio and Control

WavPack–Audio Codec

 
Network Ports

Unicast:

Port 80 TCP–System Management, Expansion

Port 6001 TCP–System Management

Port 6001 UDP–Audio Streams

Multicast: Port 5353 UDP–mDNS, Names, Discovery, Linking, Expansion

Optional for device names and linking

Mandatory for expansion mode

 
Network Parameters

HMS-4X Endpoint Resource Use: 1-3

Bandwidth: 300-600 (max) kbps from Remote Station to Arcadia/HMS-4X dependent on use of Program Audio Input 1200-2400 (max) kbps from Arcadia/HMS-4X to Remote Station dependent on use of Stage Announce Output

Network Jitter Tolerance: <= 128ms jitter buffer per audio stream receiver automatically adjusted to network performance

QoS Tags: DSCP=34, Assured Forwarding (AF=41)

Link-Local Default IP Address Range: 169.254.0.0/16

System Reserved IP Range:

10.0.0.0/24 for endpoints on HMS-4X

10.0.0.0-7 for Arcadia

 
Recommended Ethernet Switches

• Managed Ethernet Switch – Layer 3

• 100/1000 Base-T ports for endpoints

• 1000 Base IP Trunks between switches

• QoS Configuration

• Energy Efficient Ethernet bypass option

• IGMP Snooping bypass option

Mark as DiscontinuedNo
Rank9999
IsActiveTest
Please login or register to post comments.

Industry
Affiliations

NAB company logo
AIMS company logo
ASD company logo
NAMM company logo

Contacts

Contact 1

Contact 2

Contact 3

FIND A RESELLER OR RENTAL PARTNER

Whether you are looking for a simple wired intercom system for small theatre, a wireless intercom system for an outdoor live event, or a multi-system intercom network for a large-scale broadcast production.

Find a Rental Partner