Skip to main menu Skip to main content Skip to footer

IKB-12P

IKB-12 and HRI-12 intercom stations are designed to be a part of the HCS Industrial Intercom System providing a high-capacity single channel partyline intercom to intercom stations with point-to-point and point-to-multipoint audible and visual call signalling with caller identification. The stations are flush mount installation on an electrical back box. They include an active handset cradle which detects the handset and places the station into the partyline when taken off hook. 

 

Details

HCS Industrial Intercom

  • Single Channel Partyline
  • Advanced Call Signals
    • Point-To-Point
    • Point-To-Multipoint
    • Audible Buzzer
    • Visual Caller Identification

HMS-4X Main Station

  • Networked System Host
  • 1 HMS-4X* with HLI-ET2 per system
  • HCS Firmware Features
  • Cold Standby Redundancy

IKB/HRI Intercom Stations

  • Up to 64 IKB/HRI Intercom Stations
    • Handset
    • 12 Buttons for Call Signals
    • 28 GPI for Call Signals
    • IP65 Environmental Rating**

HCS Configuration & Management

  • Easy to use browser configuration
  • Fast front panel control & configuration
  • Plug-and-go with auto discovery
  • Central upgrades from main station

*Specifications and features listed here supercede the capabilities listed in the HMS-4X datasheet.
**Flush-mounted to a wall or back box, with appropriate perimeter seals.

Item Code

HMS-4X: Main Station
HLI-ET2: Ethernet Module
HCS.2.1.0: Firmware
IKB-12P: Intercom Station
HRI-12B: Intercom Station–Without logo
HRI-12M: Intercom Station–Narrow, without logo
HS-6: Handset

HCS system capabilities and IKB/HRI-12 handset stations are only compatible with the above system components.

Please call Clear-Com to reserve HMS-4X for your HCS system project

 

Technical
Specifications

HCS System Host

HMS-4X with HCS Firmware*: Supports up to 64 endpoints (IKB-12P, HRI-12B, HRI-12M). User stations can connect via the HLI-ET2 module using 3rd party network switch connection. HMS-4X allows use of 1 channel when hosting the HCS firmware.

 

IKB/HRI-12 Intercom Station

Connectors

Ethernet/PoE: RJ45
Handset: 4-pin XLR-M
GPI: (2) Terminal Block 16 Pole, 3.8mm

Microphone Pre-amplifier

Handset Mic Impedance: 200Ω (Dynamic)
Limiter: +23dB
Mic Gain: 60dB (Dynamic)
Frequency Response: 400Hz - 8kHz ± 3dB, contoured for intelligibility
Distortion: <0.1% THD @ 1kHz
Noise: <-65dBu
Headphone Limiter: 0dB (selectable)

Headphone Pre-amplifier

Load Impedance: >32Ω
Output Level: +12dBu before clipping
Sidetone: -6dB (selectable)
Max Gain: 12dB
Noise: <-65dBu
Headphone Limiter: 0dB (selectable)

Logic Input - GPI (Internal)
Assignable to Profile(s) Call signals
Input: 28
Style: Powered input, close contact to ground
Detection Voltage (Min): 3V
Input Voltage (Max): 5V
Output Voltage: 5V
Output Current (Max): 1mA

Device Power

Power (Max): 5W
BTU (Max): 17BTU/hour

This unit can be powered via:
PoE – Power over Ethernet
IEEE 802.3af-2003 - Class 0
PSE: 15.4W DC max @ Power Source Req.
PD: 12.95W DC max @ Powered Device Draw

Note: Handset Station must be earthed to a clean ground when PoE is used. Preferably with the screen of a shielded CAT5/6 cable.

 

Environmental

Humidity: 0-95%, relative
Temperature: -14° to 131°F (-10° to +55°C)

 

Dimensions

IKB-12P/HRI-12B: 8 x 10 x 3.6in (HxWxD)
(203 x 254 x 93mm)
HRI-12M: 6.3 x 11.2 x 3.6in (HxWxD)
(160 x 285 x 93mm)

 

Weight

27.9oz (0.79kg)

 

*Specifications and features listed here supercede the capabilities listed in the HMS-4X datasheet.
**Flush-mounted to a wall or back box, with appropriate perimeter seals.

Associated
Products

Ready to get
started?

Our team of communications professionals are here to support your project. Contact us today to start designing your custom intercom solution.

Sales Contacts Where to Buy/Rent