Logic Inputs – GPI
Assignable to control events or call
Input: 1 per 4-Wire GPI Port
Style: Powered input, close contact to ground
Input Voltage Range: 0 - 12V DC or AC
Input Current: >=1mA required
Logic Outputs – GPO/Relay
Assignable to control events or call
Outputs: 1 per 4-Wire GPO Port
Style: SPDT / Power Relay
Normalized: Open or Closed, separate pins
Switching Voltage (Max): 60V DC
Switching Current (Max): 2A
Power - LQ Portable Unit
DC Power Input:
Voltage: 12V DC ± 5%
Current (Max): 2A
Power (Max): 24W
BTU (Max): 82 BTU/h
Input Power Connector: KPJX-4S-S
LQ unit can be powered via DC input using:
AC Adapter - Plug-In:
Type: 453G028-1 (supplied with LQ)
Input Voltage Range: 100 - 240V AC
Input Current (Max): 0.58A
Input Frequency Range: 47-63Hz
Input Power Connector: US, UK, Europe, AUS & China included
Output Voltage: 12V DC
Output Current (Max): 2A
Output Power (Max): 24W
Output Power Connector: KPPX-4-P
PoE - Power over Ethernet: IEEE 802.3af-2003 - Class 0
PSE: 15.4W DC max @ Power Source Req.
PD: 12.95W DC max @ Powered Device Draw
Power LQ-R 1RU Rackmount Unit
(2) DC Power Input:
Voltage: 12V DC ± 5%
Current (Max): 5A
Power (Max): 60W
BTU (Max): 205 BTU/h
Input Power Connector: KPJX-4S-S
LQ-R units can be powered via the (2) DC inputs using:
AC Adapter - Inline:
Type: 453G032-2 (supplied with LQ-R)
Input Voltage Range: 100 - 240V AC
Input Current (Max): 1.4A
Input Frequency Range: 50-60Hz
Input Power Connector: IEC-C14
Output Voltage: 12V DC
Output Current (Max): 5A
Output Power (Max): 60W
Output Power Connector: KPPX-4-P
Environmental
Operating: 32° to 104°F (0° to 40°C)
Storage: -67° to 158°F (-55° to 70°C)
Humidity: 90% Non-Condensing
Dimensions
LQ-R 1RU Rackmount Unit
19 x 1.79 x 8.8in (WxHxD)
(483 x 46 x 224mm)
Weight
LQ-R
4.29lbs (1.95kg)