Channel settings: 32, 56 and 64
Sample Rates: 44.1, 48 and 96 kHz
Clock Sources: AES word clock (conforms to Annex B of AES11-2009), PAL Video B & Burst, NTSC Video B & Burst, Tri-Level HD
Bit Depth: 24 bits AES
Level Control Range: For each channel the gain shall be configurable between -72dB and +18dB
VOX Setting Range: Between -18dBFS and -63dBFS in 1dB steps
MADI BNC Connections: 75Ω single direction (pair)
Co-axial Cable Range: 50m (164 feet)
Fiber Connections: LC Duplex SFP Multi-Mode (default)
Fiber Range: 2Km (6,560 feet)
Compliances
CE, FCC Part 15. Class A UL60065
7th edition CAN/CSA C22.2 No. 60065-03 IEC60065 (2001)
7th edition Audio Engineering Society AES10-2008
Environmental
Operating Temperature: 32°F - +113°F (0°C - +40°C)
Storage Temperature: -22°F - +158°F (-30°C - +70°C)
Operating Humidity: 40 – 90%, non-condensing