Clear-Com Eclipse matrix connections
Each LQ unit (LQ 3.0 and above) can support up to 8 IVC-32 ports, as well as its own hardware ports.
- Up to 8 IVC-32 ports per LQ device
- Up to 32 IVC-32 ports per Link-Group
- IVC-32 ports are generated in the External Systems page in the CCM
- All ports, LQ hardware ports and IVC-32 ports can then be used in the LQ Channels to transmit audio, Call and GPIO signals.
Each LQ-R unit supports up to 24 ports: 8 hardware ports, 8 SIP ports and 8 virtual ports. Agent- IC and IVC ports are considered 'virtual ' ports. Virtual ports can be used in any combination up to 8 in total.
How to create virtual ports and connect to a matrix
General outline
Program the EHX software
Program the LQ CCM
Create 'virtual' ports in the CCM
Put new ports into a Channel
Once a virtual port is associated to an LQ device you can adjust the port setting. Click the cog icon to go straight to Ports page.
If you want to pass GPIO controls over the network using LQ you must program Network Control Events. See What are Networked Control Events and how do I use them?