Cable Distances - E1 Connections

 

Arcadia Station to TCVR/splitter
TCVR directly connected to and powered by the Arcadia Station
  • 328 ft (100 m) using shielded 24 AWG Cat 5/6e cable
  • 164 ft (50 m) using shielded 26 AWG Cat 5/6e cable
TCVR directly connected to the Arcadia Station with local/direct power at TCVR
  • 2625 ft (800 m) using shielded 24 AWG Cat 5/6e cable
  • 1312 ft (400 m) using shielded 26 AWG Cat 5/6e cable
Arcadia Station to splitter (splitter is powered)
  • 2625 ft (800 m) using shielded 24 AWG Cat 5/6e cable
  • 1312 ft (400 m) using shielded 26 AWG Cat 5/6e cable

 

Splitter to TCVRs
TCVRs powered by splitter
  • 328 ft (100 m) using shielded 24 AWG Cat 5/6e cable
  • 164 ft (50 m) using shielded 26 AWG Cat 5/6e cable
TCVRs have local/direct power
  • 2625 ft (800 m) using shielded 24 AWG Cat 5/6e cable
  • 1312 ft (400 m) using shielded 26 AWG Cat 5/6e cable
Note: Fiber connections: Connection distances will depend on existing cable infrastructure.